RD Series
Thermal Cut-Offs (Thermal Links) Specification

For the HVAC manufacturer...

Mounted in an insulating ceramic base, a one shot, hi-limit with configurations to suit your requirements...

RD Series Tear Drop Style

The TCO responds to temperature by interrupting an electrical circuit when the operating and /or environmental temperature exceeds the thermal rating of the fuse. This is accomplished when the organic pellet experience a phase change, allowing the spring activated contacts to permanently open the circuit.

The electrical resistance of an RD Series thermal cut-offs is comparable to that found in an equal length of 18 gauge solid copper wire. With proper air flow, heat generation below 15 Amperes is minimal. Above 15 Amperes, the upper limit on current capacity will depend on the environment for each specific application.

Thermal Cut-Offs (Thermal Links)  RDXXX-001 RDXXX-002
APPROVAL RATINGS
Type Functioning Temperature
(Tf) and Tolerance
Holding
Temperature
(Th)
Maximum Temperature
Limit (Tm)
Safety Approval
   
RD070 72 162 +0/-4℃ 65 115 UL
RD076 77 171 +0/-4℃ 67 150
RD081 84 183 +0/-4℃ 76 115
RD090 93 199 +0/-6℃ 85 315
RD098 100 212 +0/-4℃ 93 130
RD103 104 219 +0/-4℃ 98 315
RD108 109 228 +0/-4℃ 103 315
RD115 117 243 +0/-4℃ 110 130
RD118 121 250 +0/-6℃ 113 315
RD125 128 262 +0/-4℃ 119 180
RD139 141 286 +0/-6℃ 134 170
RD165 169 336 +0/-6℃ 162 270(120V) 210(250V)
RD181 184 363 +0/-4℃ 174 210
RD213 216 421 +0/-4℃ 210 375
RD226 228 442 +0/-6℃ 210 260(120V) 230(250V)
RD242 240 464 +0/-6℃ 212 375
ELECTRICAL RATINGS

<RDXXX Electrical Rating>

  Voltage(AC) Resistive Current Inductive Current
  (Vr) (Ir) (Ib) (Ir) (Ib)
UL 120V / 250V 16.7A 25A - -
120V for only D139   All types except for
D139,D226,D230

*<Note>All types are RoHS compliant.